BH-80 gas detector with imported world famous sensors and microcontrollers technology, fast response, high precision, stability and repeatability, the overall performance of the leading domestic level, the user can customize the parameters, easy to operate. High-quality lithium-ion rechargeable battery, intuitive alarm tips. Digital LCD screen display, clear and intuitive; with two level visible and audio alarming function, can be timely and accurate detect and indicate the pre-set alarm concentration, instrument appearance using a special high-strength ABS engineering plastics, stylish shape design, beautiful, feel good, durable.
2. Technical parameters:
Shell material: ABS
Dimensions: 125mm * 52mm * 30mm (L * W * H)
Explosion-proof grade: Exia II CT6
Protection class: IP65
Weight: 200g
Accuracy: ±3% F.S. (Depending on the sensor)
Detection method: Built-in pump type
Concentration unit: ppm,% VOL,% LEL, mg, m3
Alarm mode: visible and audio, vibration
Working temperature: -10 ~ 70 ºC
Operating humidity: 0 ~ 95% RH non-condensing
Working voltage: 3.6VDC
Alarm current: 150mA
Working current: Pumping 60mA
Battery capacity: 3200mA, with charging protection circuit
Charger specifications: 4.2VDC, 1A
3. Built-in pump-type gas detector application:
BH-80 gas detector with a fast response, good stability, high sensitivity, small size, light weight, easy to carry, etc., along with the built-in gas sampling pump, the measurement results more accurate and fast. Widely used in petrochemical, industrial production, flue gas exhaust environmental monitoring, sewage treatment, bio-pharmaceutical, home environmental protection, school laboratories and other fields.
Appendix: Technical performance and parameters
Main Specifications
Note: Other gases not listed can be inquired.
1. Description
BH-80 gas detector with imported world famous sensors and microcontrollers technology, fast response, high precision, stability and repeatability, the overall performance of the leading domestic level, the user can customize the parameters, easy to operate. High-quality lithium-ion rechargeable battery, intuitive alarm tips. Digital LCD screen display, clear and intuitive; with two level visible and audio alarming function, can be timely and accurate detect and indicate the pre-set alarm concentration, instrument appearance using a special high-strength ABS engineering plastics, stylish shape design, beautiful, feel good, durable.
2. Technical parameters:
Shell material: ABS
Dimensions: 125mm * 52mm * 30mm (L * W * H)
Explosion-proof grade: Exia II CT6
Protection class: IP65
Weight: 200g
Accuracy: ±3% F.S. (Depending on the sensor)
Detection method: Built-in pump type
Concentration unit: ppm,% VOL,% LEL, mg, m3
Alarm mode: visible and audio, vibration
Working temperature: -10 ~ 70 ºC
Operating humidity: 0 ~ 95% RH non-condensing
Working voltage: 3.6VDC
Alarm current: 150mA
Working current: Pumping 60mA
Battery capacity: 3200mA, with charging protection circuit
Charger specifications: 4.2VDC, 1A
3. Built-in pump-type gas detector application:
BH-80 gas detector with a fast response, good stability, high sensitivity, small size, light weight, easy to carry, etc., along with the built-in gas sampling pump, the measurement results more accurate and fast. Widely used in petrochemical, industrial production, flue gas exhaust environmental monitoring, sewage treatment, bio-pharmaceutical, home environmental protection, school laboratories and other fields.
Appendix: Technical performance and parameters
Main Specifications
Gas | Range | Accuracy | Resolution | Response time |
EX | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤10s |
EX | 0-100%Vol | <±3%F.S | 0.1%Vol | ≤10s |
CH4 | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤5s |
CH4 | 0-100%Vol | <±3%F.S | 0.1%Vol | ≤10s |
O2 | 0-30%Vol | <±3%F.S | 0.01%Vol | ≤15s |
O2 | 0-100%Vol | <±3%F.S | 0.01%Vol | ≤15s |
CO | 0-500ppm | <±3%F.S | 0.1ppm | ≤25s |
CO | 0-1000ppm | <±3%F.S | 0.1ppm | ≤25s |
CO | 0-2000ppm | <±3%F.S | 0.1ppm | ≤25s |
CO | 0-20000ppm | <±3%F.S | 1ppm | ≤25s |
CO | 0-100000ppm | <±3%F.S | 1ppm | ≤25s |
CO2 | 0-2000ppm | <±3%F.S | 1ppm | ≤20s |
CO2 | 0-5000ppm | <±3%F.S | 1ppm | ≤20s |
CO2 | 0-10000ppm | <±3%F.S | 1ppm | ≤30s |
CO2 | 0-50000ppm | <±3%F.S | 1ppm | ≤30s |
CO2 | 0-20%Vol | <±3%F.S | 0.01%Vol | ≤30s |
CO2 | 0-50%Vol | <±3%F.S | 0.01%Vol | ≤30s |
CO2 | 0-100%Vol | <±3%F.S | 0.01%Vol | ≤30s |
CH2O | 0-10ppm | <±3%F.S | 0.001ppm | ≤40s |
CH2O | 0-50ppm | <±3%F.S | 0.01ppm | ≤40s |
CH2O | 0-1000ppm | <±3%F.S | 0.1ppm | ≤50s |
O3 | 0-1ppm | <±3%F.S | 0.001ppm | ≤30s |
O3 | 0-10ppm | <±3%F.S | 0.01ppm | ≤30s |
O3 | 0-50ppm | <±3%F.S | 0.01ppm | ≤30s |
O3 | 0-100ppm | <±3%F.S | 0.01ppm | ≤30s |
O3 | 0-2000ppm | <±3%F.S | 0.1ppm | ≤40s |
H2S | 0-10ppm | <±3%F.S | 0.001ppm | ≤30s |
H2S | 0-50ppm | <±3%F.S | 0.01ppm | ≤30s |
H2S | 0-100ppm | <±3%F.S | 0.01ppm | ≤30s |
H2S | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
H2S | 0-2000ppm | <±3%F.S | 1ppm | ≤45s |
SO2 | 0-10ppm | <±3%F.S | 0.001ppm | ≤30s |
SO2 | 0-20ppm | <±3%F.S | 0.01ppm | ≤30s |
SO2 | 0-100ppm | <±3%F.S | 0.01ppm | ≤30s |
SO2 | 0-500ppm | <±3%F.S | 0.1ppm | ≤45s |
SO2 | 0-2000ppm | <±3%F.S | 1ppm | ≤60s |
SO2 | 0-5000ppm | <±3%F.S | 1ppm | ≤60s |
NO | 0-25ppm | <±3%F.S | 0.01ppm | ≤60s |
NO | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
NO | 0-2000ppm | <±3%F.S | 1ppm | ≤60s |
NO2 | 0-20ppm | <±3%F.S | 0.01ppm | ≤25s |
NO2 | 0-200ppm | <±3%F.S | 0.1ppm | ≤25s |
NO2 | 0-1000ppm | <±3%F.S | 0.1ppm | ≤50s |
NO2 | 0-5000ppm | <±3%F.S | 0.1ppm | ≤50s |
CL2 | 0-10ppm | <±3%F.S | 0.001ppm | ≤30s |
CL2 | 0-20ppm | <±3%F.S | 0.01ppm | ≤30s |
CL2 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
NH3 | 0-50ppm | <±3%F.S | 0.01ppm | ≤50s |
NH3 | 0-100ppm | <±3%F.S | 0.01ppm | ≤50s |
NH3 | 0-1000ppm | <±3%F.S | 0.1ppm | ≤60s |
NH3 | 0-5000ppm | <±3%F.S | 1ppm | ≤60s |
NH3 | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤10s |
H2 | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤10s |
H2 | 0-1000ppm | <±3%F.S | 0.1ppm | ≤60s |
H2 | 0-20000ppm | <±3%F.S | 1ppm | ≤60s |
H2 | 0-40000ppm | <±3%F.S | 1ppm | ≤60s |
H2 | 0-100%Vol | <±3%F.S | 0.1%Vol | ≤30s |
HCN | 0-30ppm | <±3%F.S | 0.01ppm | ≤60s |
HCN | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
HCL | 0-20ppm | <±3%F.S | 0.01ppm | ≤60s |
HCL | 0-200ppm | <±3%F.S | 0.1ppm | ≤60s |
PH3 | 0-5 ppm | <±3%F.S | 0.001ppm | ≤25s |
PH3 | 0-25 ppm | <±3%F.S | 0.01ppm | ≤25s |
PH3 | 0-2000 ppm | <±3%F.S | 1ppm | ≤60s |
CLO2 | 0-1ppm | <±3%F.S | 0.001ppm | ≤40s |
CLO2 | 0-10ppm | <±3%F.S | 0.01ppm | ≤40s |
CLO2 | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
ETO | 0-100ppm | <±3%F.S | 0.01ppm | ≤120s |
ETO | 0-1000ppm | <±3%F.S | 0.1ppm | ≤120s |
ETO | 0-100%LEL | <±3%F.S | 1%LEL | ≤30s |
COCL2 | 0-1ppm | <±3%F.S | 0.001ppm | ≤50s |
SiH4 | 0-1ppm | <±3%F.S | 0.001ppm | ≤60s |
SiH4 | 0-50ppm | <±3%F.S | 0.01ppm | ≤60s |
F2 | 0-1ppm | <±3%F.S | 0.001ppm | ≤60s |
F2 | 0-10ppm | <±3%F.S | 0.01ppm | ≤60s |
F2 | 0-100ppm | <±3%F.S | 0.1ppm | ≤60s |
HF | 0-10ppm | <±3%F.S | 0.01ppm | ≤40s |
HF | 0-50ppm | <±3%F.S | 0.01ppm | ≤40s |
H8r | 0-50ppm | <±3%F.S | 0.07ppm | ≤60s |
82H6 | 0-10ppm | <±3%F.S | 0.001ppm | ≤60s |
AsH3 | 0-1ppm | <±3%F.S | 0.007ppm | ≤60s |
AsH3 | 0-10ppm | <±3%F.S | 0.01ppm | ≤60s |
GeH4 | 0-2ppm | <±3%F.S | 0.001ppm | ≤60s |
GeH4 | 0-20ppm | <±3%F.S | 0.01ppm | ≤60s |
N2H4 | 0-1ppm | <±3%F.S | 0.001ppm | ≤60s |
N2H4 | 0-300ppm | <±3%F.S | 0.1ppm | ≤60s |
THT | 0-50mg/m3 | <±3%F.S | 0.01 mg/m3 | ≤60s |
Br2 | 0-10ppm | <±3%F.S | 0.001ppm | ≤60s |
Br2 | 0-50ppm | <±3%F.S | 0.01ppm | ≤60s |
C2H2 | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤30s |
C2H2 | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
C2H2 | 0-1000ppm | <±3%F.S | 0.1ppm | ≤60s |
C2H4 | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤30s |
C2H4 | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
C2H4 | 0-1000ppm | <±3%F.S | 0.1ppm | ≤60s |
C2H4O | 0-10ppm | <±3%F.S | 0.01ppm | ≤60s |
C2H6O | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤30s |
C2H6O | 0-100ppm | <3%F.S | 0.07ppm | ≤60s |
C2H6O | 0-2000ppm | <±3%F.S | 1ppm | ≤60s |
CH6O | 0-100%LEL | <±3%F.S | 0.1%LEL | ≤30s |
CH6O | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
CH6O | 0-2000ppm | <±3%F.S | 1ppm | 60s |
CS2 | 0-50ppm | <±3%F.S | 0.01ppm | ≤60s |
C3H3N | 0-50ppm | <±3%F.S | 0.01ppm | ≤60s |
C3H3N | 0-100ppm | <±3%F.S | 0.01ppm | ≤60s |
C3H3N | 0-2000ppm | <±3%F.S | 1ppm | ≤30s |
CH3NH2 | 0-50ppm | <±3%F.S | 0.01ppm | ≤60s |
SO2F2 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
SO2F2 | 0-20ppm | <±3%F.S | 0.1ppm | ≤30s |
N2 | 0-100%Vol | <±3%F.S | 0.01%Vol | ≤30s |
I2 | 0-50ppm | <±3%F.S | 0.01ppm | ≤30s |
NOX | 0-100ppm | <±3%F.S | 0.01ppm | ≤30s |
C6H6 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C7H8 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C8H10 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C8H8 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C8H8 | 0-6000ppm | <±3%F.S | 1ppm | ≤30s |
C2H3CL | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C2HCL3 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
C2CL4 | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
CH3Br | 0-200ppm | <±3%F.S | 0.1ppm | ≤30s |
Product Categories : Instruments & Meters
Premium Related Products
Other Products
Hot Products
Hot Sale Hydraulic Tools Shearing Bending India Busbar Machine For SwitchboardsGood price PLW-125 hydraulic busbar bending toolGood price HYB-150 hydraulic embossing busbar toolZHH-700S hydraulic hand electric Piston gasoline pumpCFP-800-1 hydraulic foot piston pumpChina CP-180 hydraulic hand electric piston pumpFCY-50200 hydraulic piston cylinder tools for liftingChina good CTE-25AS Hydraulic electric pumpChinese Qc11Y-8X4000 Shearing Cnc Machine Price Sheet Metal Press Brake2017 Top We67K 160/2500 Knife New Press BrakeChina factory CH-100A hydraulic punching steel hole punching toolChina best panel cnc fabricated low price brass busbar machine Shearing MachineChina best WC67K panel cnc fabricated portable busbar machine Press BrakeHigh Quality Multifunction Cnc Busbar Punching Shearing Machine ZXMX302-7CChina copper sheet punching tool bending machine hydraulic busbar extruderLow Height Hydraulic Cylinders